Free CRCST flashcards
251 key terms from the study guide. No account needed. Cards you know come back less often, so you spend your time on the ones you don't.
All CRCST key terms
Work Environment, Air and Chemical Safety
- Negative pressure
- A room held at lower air pressure than its neighbors, so air flows into it; used for decontamination.
- Positive pressure
- A room held at higher air pressure than its neighbors, so air flows out of it; used for sterile storage.
- Air changes per hour
- How many times the full volume of a room's air is replaced in one hour.
- Relative humidity
- The amount of moisture in the air, given as a percentage of the most the air could hold at that temperature.
- Smoke tube
- A device that releases a visible wisp at a doorway so staff can see which way air is moving.
- Flutter strip
- A light paper or plastic strip hung at a door gap that bends in the direction of airflow.
- Safety Data Sheet (SDS)
- A 16-section document from the maker of a chemical describing its hazards, safe handling, first aid, spill response and disposal.
- Hazard Communication Standard
- OSHA rule 29 CFR 1910.1200 requiring chemical labels, data sheets and worker training about chemical hazards.
- Workplace container
- A bottle or other vessel a worker fills from the original product for use on the job; it must be labeled.
- Product identifier
- The name or number on a chemical's label that links it to its matching data sheet.
- Eyewash station
- Plumbed or self-contained equipment that flushes the eyes with a steady stream of water after a chemical splash.
- Glutaraldehyde
- A high-level disinfecting chemical that can sting the eyes, inflame the skin and irritate the airways.
Attire, Traffic Control and Ergonomics
- Hand hygiene
- Cleaning the hands by washing with soap and water or rubbing in an alcohol-based product.
- Alcohol-based hand sanitizer
- A rub-in hand product preferred by CDC when hands are not visibly soiled; rub until dry, about 20 seconds.
- Visibly soiled hands
- Hands with dirt, blood or other matter you can see; they must be washed with soap and water.
- Gram-negative bacteria
- A large group of bacteria, including Pseudomonas and Klebsiella, found more often on the fingertips of workers wearing artificial nails.
- Bloodborne Pathogens standard
- OSHA rule 29 CFR 1910.1030 that protects workers exposed to blood and other potentially infectious materials.
- Traffic control
- Limiting who enters each area and how people and items move, so contamination does not travel from dirty to clean.
- One-way workflow
- Moving items only from decontamination to packaging to sterilization to storage, never back toward dirty areas.
- Limited-access area
- A space, such as sterile storage, entered only by staff who need to work there.
- Ergonomics
- Fitting a job to a person to reduce fatigue and work-related muscle, nerve and tendon injuries.
- Musculoskeletal disorder (MSD)
- An injury or illness of the muscles, nerves, tendons, ligaments or blood vessels, often from repeated strain.
- Engineering control
- A physical change to the workplace, such as an adjustable table, that removes or reduces a hazard; OSHA's top choice.
- Administrative control
- A rule or procedure, such as job rotation or scheduled breaks, used when physical changes are not enough.
- Power zone
- The safest lifting area: between knee and shoulder height, with the load held near the body.
Regulations, Standards, Records and Quality
- FDA
- Federal agency that regulates medical device makers and clears sterilants and high-level disinfectants for devices.
- EPA
- Federal agency that registers disinfectants for environmental surfaces such as floors and countertops.
- OSHA
- Federal agency that sets and enforces rules to keep workers safe and healthy on the job.
- Conditions of Participation
- CMS health and safety requirements an organization must meet to take part in Medicare and Medicaid.
- Deemed status
- Recognition that a facility accredited by a CMS-approved organization meets Medicare requirements.
- Consensus standard
- A voluntary practice document written by a standards development organization such as AAMI.
- Instructions for use (IFU)
- The manufacturer's validated written directions for using, cleaning and processing a specific device.
- FIFRA
- The federal pesticide law under which EPA registers surface disinfectants and makes their labels legally binding.
- Load number
- A code on each package linking it to the sterilizer cycle that processed it, for tracing and recalls.
- MedWatch
- FDA's program for safety information and adverse event reports; voluntary reports use Form FDA 3500.
- User facility reporting
- FDA rule requiring hospitals to report device-related deaths and serious injuries within 10 work days.
- Competency testing
- Documented checks that a worker can do each task correctly, done at hire and regularly after.
- PDSA
- Plan-Do-Study-Act: an improvement cycle built on small tests of change before wider adoption.
- Lean
- An improvement method that raises efficiency by removing steps that add no value.
- Six Sigma
- A data-driven improvement method that reduces variation and defects using Define-Measure-Analyze-Improve-Control.
- Root cause analysis (RCA)
- A structured review of a serious event to find underlying system problems instead of individual blame.
Decontamination Safety, PPE and Microbiology
- Chain of infection
- Five linked steps (reservoir, exit, transmission, entry, host) that an infection needs; breaking one stops it.
- Fomite
- Inanimate object, such as a used instrument, that carries organisms from one person to another.
- Indirect transmission
- Spread of an infectious agent through a go-between such as an object, air particle or insect.
- Biofilm
- Community of microbes tightly attached to a surface, far more resistant to germicides than free-floating cells.
- Bacterial spore
- Dormant bacterial form protected by a coat and cortex; the most chemical-resistant organism after prions.
- Mycobacteria
- Bacteria such as M. tuberculosis whose waxy cell wall makes them resist many disinfectants.
- Exposure incident
- Blood or infectious material reaching eye, mouth, mucous membrane, broken skin or a puncture during work.
- Engineering control
- Device that isolates or removes a hazard, such as a sharps container.
- Work practice control
- Change in how a task is done to cut exposure, such as no eating in the work area.
- Hepatitis B declination
- Signed form refusing the HBV vaccine; the worker may still accept the shots later, free.
- Post-exposure evaluation
- Confidential, free medical assessment and follow-up the employer provides after an exposure incident.
- Biohazard label
- Fluorescent orange or orange-red warning tag with the symbol; red bags or containers may substitute.
- Donning
- Putting on protective gear in order: gown, mask, eye protection, then gloves over the cuffs.
- Doffing
- Removing protective gear; in CDC's first example gloves come off first and the mask last.
- Prion
- Infectious protein that causes CJD and is not reliably inactivated by routine reprocessing.
- High-infectivity tissue
- For CJD: brain, spinal cord and eye, which call for special instrument reprocessing.
Manual and Mechanical Cleaning
- Point-of-use treatment
- Keeping used instruments open and moist right after the procedure; it starts but never replaces cleaning.
- Friction
- Rubbing or scrubbing soil off with a brush or cloth; one of two essentials of manual cleaning.
- Fluidics
- Fluid forced under pressure through channels to flush out soil, especially where a brush cannot pass.
- Enzymatic cleaner
- Detergent with proteases (and sometimes lipases or amylases) that digests soil but kills no microbes.
- Neutral pH detergent
- Cleaning solution that is neither acidic nor alkaline; with enzymes it is CDC's preferred choice for delicate instruments and flexible endoscopes.
- Alkaline cleaner
- High-pH detergent that dissolves protein and fat efficiently but can corrode devices.
- Cavitation
- Formation and implosion of tiny bubbles from sound waves, which pulls debris off instruments in an ultrasonic unit.
- Degassing
- Running a freshly filled ultrasonic unit with the lid closed for 5 to 10 minutes to remove dissolved gas.
- Impingement
- Pressurized water spray that physically knocks soil off; the main cleaning action of a washer-disinfector.
- Thermal rinse
- Final hot-water step of a washer-disinfector cycle that disinfects by heat.
- Test soil
- Commercial product mimicking dried blood, used to check that a washer-disinfector is cleaning properly.
- Cart washer
- Machine for carts, rigid containers and basins; lacks enzymatic wash and lubrication steps.
- Pyrogen-free water
- Water free of fever-causing substances such as endotoxin; required for final rinsing of intravascular device lumens.
- TASS
- Toxic anterior segment syndrome: acute, noninfectious eye inflammation after anterior segment surgery, often from instrument residue.
- Single-use device
- Item intended for one use or one patient in one procedure, then discarded.
- Instructions for use (IFU)
- Manufacturer's written directions for reprocessing a device or using a chemical; they set disassembly, dilution, temperature and method.
Spaulding Classification and Disinfection
- Critical item
- Device entering sterile tissue or the vascular system, such as a surgical instrument; must be sterile.
- Semicritical item
- Device touching mucous membranes or nonintact skin, such as a laryngoscope blade; needs at least high-level disinfection.
- Noncritical item
- Device touching only intact skin, such as a blood pressure cuff; needs low-level disinfection.
- High-level disinfection
- Process killing all microorganisms except small numbers of bacterial spores.
- Intermediate-level disinfectant
- Chemical that kills vegetative bacteria including tubercle bacilli, fungi, lipid and some nonlipid viruses, but not spores.
- Low-level disinfectant
- Chemical that kills most vegetative bacteria, lipid viruses and some fungi, but not tubercle bacilli or spores.
- Chemical sterilant
- Germicide that kills spores when given long contact, often 3 to 12 hours.
- Minimum effective concentration (MEC)
- Lowest strength at which a reusable disinfectant still meets its label claim; checked with test strips.
- Reuse life
- Maximum number of days a reusable solution may be used, set by its manufacturer, regardless of strip results.
- Glutaraldehyde
- Metal-safe high-level disinfectant whose vapor irritates airways and skin; needs ventilation and nitrile or butyl gloves.
- Ortho-phthalaldehyde (OPA)
- High-level disinfectant that stains proteins, including unprotected skin, gray.
- Peracetic acid
- Sporicidal chemical leaving no residue that can corrode copper, brass, bronze and plain steel.
- Sodium hypochlorite
- Bleach; fast and cheap but corrosive at high strength and releases chlorine gas with ammonia or acid.
- Quaternary ammonium compound
- Low-level surface disinfectant for noncritical items; not sporicidal and generally not tuberculocidal.
- FIFRA
- Federal law under which EPA registers disinfectants; using a product against its label is a violation.
- Phenolic
- EPA-registered surface disinfectant, not cleared for high-level use, kept off occupied infant bassinets.
Instrument Inspection, Testing and Care
- Box lock
- The hinged joint where the two halves of a clamp or hemostat cross; a common place for hidden soil and cracks.
- Serrations
- Grooves or ridges cut into instrument jaws to improve grip; they trap debris and need close inspection.
- Ratchet
- Interlocking teeth near the finger rings that hold an instrument's jaws closed at set positions.
- Function check
- Testing that an instrument works as intended, such as jaw alignment, ratchet hold, smooth hinges and sharp edges.
- Retained soil
- Blood, tissue or other debris left on a device after cleaning, which can shield microbes from sterilization.
- Insulation tester
- A device that detects breaks in the coating of electrosurgical instruments that could let current escape.
- Cannulated device
- An instrument with a hollow channel, such as a suction tip, checked to confirm the channel is open.
- Passive layer
- The thin chromium and iron oxide film on stainless steel that protects it from rust.
- Pitting
- Small dark holes where metal has been lost to corrosion, often from blood, chlorides or harsh solutions.
- Spotting
- Loose deposits sitting on an instrument's surface, often minerals from hard water, that can be wiped away.
- Galvanic corrosion
- Metal transferring from one metal to another when dissimilar metals share a solution, leaving rainbow, gold or rusty tints.
- Water-soluble lubricant
- An instrument lubricant that dissolves in water, so it does not block sterilant from reaching the metal.
- Instructions for use (IFU)
- The manufacturer's written directions for cleaning, testing, lubricating and sterilizing a specific device.
- Deionized water
- Water with dissolved minerals removed, used for final rinsing to prevent spots and deposits.
Set Assembly and Chemical Indicators
- Tray list
- The count sheet naming every device a set should contain, used to check completeness during assembly.
- Stringer
- A pin or rack that holds ringed instruments together, open, inside a tray.
- First ratchet
- The lightest locked position on a ratcheted instrument, the only closed position allowed in a set.
- Tip protector
- A cover over a sharp end, validated for steam penetration and fitted loosely enough for sterilant to reach.
- Wet pack
- A package with moisture inside the case or tray after the cycle ends; its contents are considered contaminated.
- External chemical indicator
- A marker on the outside of a package showing it went through a cycle, not that it is sterile.
- Internal chemical indicator
- A marker placed inside a package to show the sterilant reached the contents.
- Process indicator
- ISO 11140 Type 1; shows a pack was exposed to the process, separating processed from unprocessed units.
- Integrating indicator
- ISO 11140 Type 5; reacts to all critical variables and is meant to equal or exceed biological indicator performance requirements.
- Emulating indicator
- ISO 11140 Type 6; reacts to all critical variables and matches those of a specified cycle.
- Bowie-Dick test
- A daily empty-chamber check of air removal and air leaks in a prevacuum steam sterilizer.
- Biological indicator
- A test containing resistant spores; the only monitor that measures whether a cycle killed microbes.
- Quarantine
- Holding processed items back from use until a pending test result, such as a spore test, comes back.
- Loaner set
- Instruments borrowed from a vendor or another facility for a procedure, processed here per the maker's instructions before use.
- Immediate-use steam sterilization
- A shortened steam cycle for items needed at once; the WHO manual says never to use it for implants.
Packaging Methods and Labeling
- Sterile barrier
- Packaging that lets sterilant in, then blocks microbes so contents stay sterile until opened.
- Sequential wrapping
- Two sheets wrapped one after the other, creating a package within a package.
- Simultaneous wrapping
- Two sheets laid together and folded as one, giving two layers with a single wrapping step.
- Envelope fold
- A wrapping method with the set placed diagonally, slightly off center, and the corners folded over it.
- Square fold
- A wrapping method, also called parcel fold, with the set centered and parallel to the wrap's long edge.
- Tenting
- Loose wrap standing away from the contents, leaving air pockets that can compromise the barrier.
- Peel pouch
- A heat-sealed paper-plastic or synthetic package for a single, lightweight device.
- Heat sealer
- A machine that closes pouches with heat and pressure; tested daily and calibrated at least yearly.
- Rigid container
- A reusable metal or polymer box with filtered vents, used mainly for large steam-sterilized sets.
- Tyvek
- A synthetic polyolefin material with low chemical absorption, suitable for hydrogen peroxide plasma packaging.
- Load number
- Label code identifying the sterilizer, the cycle or load, the date and any expiration date.
- Event-related shelf life
- Treating an item as sterile until damage, moisture, a broken seal or other event compromises it.
- Batch control label
- A peel-off label recording lot details, placed in the patient's record to allow tracing and recall.
- Indicator tape
- Adhesive tape that closes wrapped packs and carries a process indicator that changes color in a cycle.
Steam and High-Temperature Sterilization
- Gravity displacement
- Air removal in which incoming steam, lighter than air, pushes air down and out through a drain near the bottom.
- Dynamic air removal
- Active air removal before exposure, either by vacuum pulses (prevacuum) or by steam flushes and pressure pulses.
- Prevacuum sterilizer
- Steam unit that uses a vacuum pump or ejector to pull air out of the chamber and load before exposure.
- Steam-flush pressure-pulse
- Air-removal method using repeated steam flushes and pulses above atmospheric pressure, so leaks cannot draw air in.
- Conditioning
- First cycle phase, when air is removed and the load is heated.
- Exposure time
- Period the load is held at the set sterilizing temperature.
- Jacket
- Steam-filled space around the chamber that preheats it and helps dry the load.
- Door gasket
- Seal between the door and chamber that keeps steam and pressure inside.
- Thermostatic trap
- Drain-line device that lets condensate leave the chamber, helping loads dry.
- Drain strainer
- Screen over the chamber drain that catches lint and debris; clean it daily.
- Dryness fraction
- Share of steam that is vapor rather than liquid water; at least 97% is the goal.
- Wet pack
- Package with dampness, droplets or puddles on or inside it after the cycle; treated as contaminated.
- Immediate-use steam sterilization
- Unwrapped steam processing of an item needed right away; also called flash; no storage afterward.
- Porous item
- Item that can trap air or liquid, such as fabric, rubber, plastic or a device with a lumen.
Low-Temperature Sterilization
- Ethylene oxide (EtO)
- Flammable, carcinogenic sterilant gas used for heat- and moisture-sensitive devices; requires aeration afterward.
- Aeration
- Holding items after an EtO cycle, in an aerator or room, until the gas they absorbed has left them.
- Preconditioning
- First EtO cycle stage, when the load is brought to set conditions and humidified before gas enters.
- Permissible exposure limit (PEL)
- OSHA's maximum allowed worker exposure; for EtO, 1 ppm averaged over 8 hours.
- Excursion limit
- OSHA's short-term EtO cap: 5 ppm averaged over 15 minutes.
- Action level
- EtO exposure of 0.5 ppm over 8 hours; reaching it 30 or more days a year requires medical surveillance.
- Time-weighted average (TWA)
- A worker's average airborne chemical concentration across a set sampling period, such as an 8-hour shift.
- Hydrogen peroxide gas plasma
- Low-temperature vacuum process using peroxide vapor and plasma; leaves water and oxygen, so no aeration.
- Cellulose
- Plant-based material such as paper or cotton linen; absorbs hydrogen peroxide, so it cannot go in peroxide sterilizers.
- Polyolefin pouch
- Synthetic (Tyvek-type) peel pouch acceptable for hydrogen peroxide sterilization.
- Peracetic acid system
- Automated liquid immersion sterilizer for immersible heat-sensitive instruments; items must be used immediately.
- Channel connector
- Fitting that links an endoscope's lumens to the processor so liquid sterilant flows through them.
- Ozone sterilizer
- Low-temperature unit that generates its oxidizing gas from oxygen, water and electricity, then converts it back with a catalyst.
- Dry heat
- Hot-air sterilization, e.g. 170°C for 60 minutes, for powders, oils and petroleum products.
Sterilizer Testing, Load Release and Recalls
- Physical monitor
- Printout, graph or display showing a cycle's time, temperature and pressure; also called mechanical monitoring.
- External chemical indicator
- Indicator on a package's outside showing only that it was exposed to a sterilization process.
- Internal chemical indicator
- Indicator placed inside a package to show sterilant reached the contents.
- Process indicator
- ISO Type 1 marker, such as tape, separating processed from unprocessed packages.
- Integrating indicator
- ISO Type 5 device reacting to all critical variables, designed to perform at or beyond BI requirements.
- Emulating indicator
- ISO Type 6 device reacting to all critical variables, matched to the specific cycle on its label.
- Bowie-Dick test
- Daily empty-chamber air-removal check for prevacuum steam sterilizers, run before the first load.
- Leak test
- Vacuum check of whether a prevacuum chamber is airtight, run on the sterilizer maker's schedule.
- Biological indicator (BI)
- Carrier of resistant spores that shows whether a cycle actually killed organisms.
- Geobacillus stearothermophilus
- Spore-former used to monitor steam (and per CDC peroxide plasma and peracetic acid); incubated at 55-60°C.
- Bacillus atrophaeus
- Spore-former used to monitor EtO and dry heat; incubated at 35-37°C.
- Control BI
- Unprocessed indicator from the same lot, incubated to prove the spores could grow.
- Process challenge device (PCD)
- Test pack or tray that challenges the cycle and holds a BI, integrating indicator or enzyme-only indicator.
- Quarantine
- Holding processed items, such as implants, until monitoring results allow release.
- Recall
- Retrieving items from suspect loads so they can be reprocessed and patient exposure assessed.
- Load label
- Package marking naming the sterilizer, cycle or load number, date and any expiration, enabling tracing.
Sterile Storage, Shelf Life and Transport
- Sterile storage
- A limited-access area with controlled temperature and humidity where processed packs are kept until issue.
- Event-related shelf life
- The practice of treating a pack as sterile until damage, wetting or another event compromises it.
- Time-related shelf life
- The practice of labeling packs with an expiration date and reprocessing them once that date passes.
- Package integrity
- The condition of a wrap, pouch or container being whole, dry and sealed, with no tears or punctures.
- Impervious packaging
- Material, such as heat-sealed plastic, that does not let moisture or microbes pass through.
- Stock rotation
- Placing newer items behind older ones so the oldest are used first; also called first in, first out.
- First in, first out (FIFO)
- Using the oldest stock of an item before newer deliveries of the same item.
- Open shelving
- Uncovered racks for supplies; allowed by CDC, though closed or covered cabinets are ideal.
- Sprinkler clearance
- The 18-inch space CDC calls for between stored items and a ceiling fire sprinkler head.
- Corrugated cardboard
- Ridged material used for shipping boxes; such boxes are never taken into sterile storage areas.
- Closed cart
- A transport cart with walls, doors or a cover that protects its load while outside the department.
- Reprocessing
- Repeating cleaning, inspection, packaging and sterilization so an item can be used safely again.
Inventory, Supply Chain and Distribution
- PAR level
- The set quantity of an item a location should hold; restocking brings it back to that number.
- Exchange cart
- One of a set of identical stocked carts; a full one is swapped in while the used one is refilled.
- Case cart
- A cart holding the instruments and supplies for one surgical procedure, which then returns the used items.
- Code cart
- A crash cart of emergency drugs and equipment, stocked to the facility's approved contents list.
- Just-in-time inventory
- Receiving supplies only as they are needed, which lowers stock on hand but leaves little backup.
- Consignment inventory
- Supplier-owned stock kept at the facility, paid for only when an item is used.
- Inventory turnover
- How quickly stock is used and replaced; slow movement points to overstock and expiring items.
- Unit of measure
- The packaging quantity an item is counted and issued in, such as each, box or case.
- Unique Device Identifier (UDI)
- An FDA-required code on device labels that lets a device be identified from distribution through use.
- Device identifier (DI)
- The fixed part of a device's label code naming the labeler and the model or version.
- Production identifier (PI)
- The variable part of a device's label code: lot, serial number, expiration and manufacture dates.
- GUDID
- FDA's Global Unique Device Identification Database, which stores the device-identifier portion of each UDI.
- AIDC
- Automatic identification and data capture: machine-readable formats such as barcodes.
- Class I recall
- FDA's most serious recall category: a reasonable chance of serious health problems or death.
- Correction
- A recall action that fixes a device problem where the device is used, without removing it.
- Quarantine
- Holding processed items back from use until test results, such as a biological indicator, come back negative.
Patient Care Equipment
- Noncritical item
- Equipment that touches only intact skin or no patient at all; needs cleaning plus low-level disinfection.
- Spaulding classification
- A system sorting devices as critical, semicritical or noncritical by infection risk, which sets the processing level.
- Low-level disinfection
- Killing most vegetative bacteria and some fungi and viruses; the level CDC recommends for noncritical items.
- Contact time
- How long a disinfectant must stay wet on a surface to work, as stated on its label.
- EPA-registered disinfectant
- A surface germicide whose label claims and directions are approved by the Environmental Protection Agency and legally binding.
- Cross-contamination
- Spread of microbes from soiled items or surfaces to clean ones.
- Single-patient-use item
- A part, such as a compression sleeve, meant for one patient and discarded rather than reprocessed.
- Biomedical (Clinical) Engineering
- The hospital department that inspects, maintains and repairs medical equipment.
- Preventive maintenance (PM)
- Scheduled inspection, testing and servicing of equipment by qualified staff, documented on a label or record.
- Grounding prong
- The third plug pin that keeps equipment connected to ground; altering it or bypassing it with an adapter is prohibited.
- Function check
- A test before issue that equipment powers on and works as its manufacturer's instructions describe.
- Equipment inventory
- A list of all hospital equipment, owned or leased, with each item's maintenance record.
Communication, Teamwork and Professional Growth
- Protected health information (PHI)
- Identifiable information about a person's health, care or payment for care, in any form: paper, electronic or spoken.
- HIPAA
- The federal law whose Privacy Rule sets how health care organizations must protect identifiable patient information.
- Minimum necessary
- The rule that uses and disclosures of patient information are limited to what the task actually requires.
- Workforce
- Employees, volunteers, trainees and others under a facility's direct control, whether paid or not.
- Business associate
- An outside person or company that handles patient information on a covered entity's behalf.
- Hostile work environment
- A workplace made offensive by harassment that is severe or frequent, based on a protected trait.
- Mutual support
- Team members checking each other's work and offering help when a teammate is overloaded.
- SBAR
- A four-part reporting script: Situation, Background, Assessment, Recommendation.
- Handoff
- Passing responsibility for work, and the information about it, from one person or shift to the next.
- Near miss
- An event that did not injure a patient only because of luck or a timely catch.
- Culture of safety
- A workplace where staff report errors without fear of blame so system causes can be fixed.
- Just culture
- An approach that fixes system problems while still holding people accountable for risky or reckless choices.
- Continuing education (CE)
- Ongoing learning credits; CRCST renewal needs 12 technical, sterile processing credits each year.
- Suspension
- The status after a missed renewal: not considered certified and not allowed to use the title.
- Grace period
- The six weeks after a missed renewal date when late CE and fees can still be submitted.
Medical Terminology and Instruments
- -ectomy
- Suffix meaning to cut out or surgically remove.
- -otomy
- Suffix meaning a surgical incision or cutting into, without necessarily removing anything.
- -ostomy
- Suffix meaning a surgically created opening from inside the body to the outside.
- -plasty
- Suffix meaning surgical repair or reconstruction.
- -scopy
- Suffix meaning examination of the inside of the body with a viewing instrument.
- Stoma
- The opening on the skin created by an ostomy procedure.
- Supine
- Lying flat on the back, face up.
- Prone
- Lying flat on the front, face down.
- Proximal
- Closer to the point where a limb attaches to the trunk.
- Distal
- Farther from the point where a limb attaches to the trunk.
- Sagittal plane
- A vertical plane that divides the body into right and left parts.
- Frontal (coronal) plane
- A vertical plane that divides the body into front and back parts.
- Transverse plane
- A horizontal plane that divides the body into upper and lower parts.
- Hemostat
- A locking clamp with serrated jaws used to close off blood vessels and control bleeding.
- Box lock
- The pinned hinge of a ringed instrument that keeps the jaw tips aligned.
- Ratchet
- Interlocking teeth near the finger rings that hold an instrument's jaws closed.
- Serrations
- Grooves cut across an instrument's jaws to help them grip tissue.
- Tungsten carbide insert
- A very hard, wear-resistant jaw or blade piece, usually marked by gold handles.
- Self-retaining retractor
- A tissue-spreading instrument that holds itself open with a ratchet or similar mechanism, needing no assistant.
- Rongeur
- A sturdy bone-cutting instrument whose sharp, scoop-shaped tip bites off pieces of bone.