This topic covers how air pressure, air changes, temperature and humidity protect each zone of the department, how the department itself is cleaned, and the OSHA rules for working safely with chemicals. Learn which way air should move in each room, which source each number comes from, and what a technician should do when something is out of range.
Air pressure keeps dirt where it belongs
Air flows from a room with higher pressure into a room with lower pressure. Ventilation is set up so air always moves from clean spaces toward dirty ones, never the other way.
- Decontamination is kept at **negative** pressure: air is pulled in from the hallway and nearby rooms, so contamination stays inside.
- Sterile storage is kept at **positive** pressure: air pushes out of the room, so dust and less-clean air from nearby spaces cannot drift onto sterile packs.
- The clean workroom (preparation and packaging) is also listed as positive, or air moving out.
- Equal pressure between rooms is not the goal; with no pressure difference there is no containment.
- Pressure is set by design and should stay the same the whole time the area is in use.
- Doors between zones only work as barriers when they are closed. A door propped open with a cart lets dirty and clean air mix, so move the cart and shut the door.
Air changes and exhaust: know your source
The CDC 2003 Guidelines for Environmental Infection Control include a ventilation table (Appendix B, Table B.2). Its central supply rows say:
- Soiled or decontamination room: air moves in (negative), at least 6 total air changes per hour, all air exhausted directly outdoors, and no recirculation by in-room heating or cooling units.
- Clean workroom: air moves out (positive), at least 4 air changes per hour.
- Sterile storage: air moves out (positive), at least 4 air changes per hour.
- For comparison, the same table lists 2 air changes for clean linen storage and 15 for operating and trauma rooms.
- Air from the decontamination room goes straight outside so it is never sent on to other parts of the building, least of all sterile storage.
- The CDC 2008 Guideline for Disinfection and Sterilization cites the American Institute of Architects (negative pressure and at least 6 air changes per hour in decontamination) and notes that AAMI recommends 10. When a question names a source, answer with that source's number.
Checking airflow and reacting to a problem
- Quick visual checks of airflow direction: a smoke tube, a flutter strip, a ping-pong ball or a tissue held in the air stream at the door gap.
- Calibrated gauges (manometers) give a number and are what engineering prefers for daily readings.
- A Bowie-Dick test, an ATP swab or a room thermometer cannot show which way air is moving.
- If a monitor shows decontamination is positive instead of negative, report it at once to the supervisor and facilities engineering, and keep the doors closed until it is fixed.
- Do not wait for the next scheduled inspection, do not move soiled carts into the clean side, and do not open doors to other rooms to try to even out the pressure.
Temperature and humidity
- CDC 2003: for most health-care areas the comfort range is 30% to 60% relative humidity.
- CDC 2003: relative humidity above 60% promotes the growth of fungi such as mold.
- CDC 2008: humidity should be 30% to 60% in work areas, except sterile storage, where it should not go above 70%.
- CDC 2008: sterile storage should have restricted entry and a controlled temperature of no more than 75°F (24°C).
- Your department's written policy may set its own limits. Follow it, and when a question names CDC 2008, use 70% and 75°F.
- If a storage reading is out of range, tell the supervisor so facilities can fix the cause, and help inspect stored packs. A package that has become wet is treated as contaminated.
- Never switch off the room ventilation to keep moist air out; that removes the positive pressure that protects sterile items.
Cleaning the department itself
- Work from cleaner areas toward dirtier areas, so soil is not carried into spaces already cleaned.
- Work from high to low: counters and other surfaces first, floors last, so falling debris lands on surfaces not yet cleaned.
- Do not use one cloth everywhere; it moves contamination from surface to surface.
- Mop and bucket solutions become contaminated almost as soon as cleaning starts, and each later surface gets more microbes, so change solutions often and launder or replace mop heads and cloths.
Hazard communication (OSHA 29 CFR 1910.1200)
- The employer must keep a Safety Data Sheet (SDS) for every hazardous chemical in use and make it readily accessible to employees in their work area during every shift. Electronic access is fine if nothing blocks immediate access.
- Staff must be able to reach the SDS themselves; it is not held by a safety officer or supervisor and given out on request.
- SDS sections to know: Section 4, first-aid measures; Section 6, accidental release measures (spill cleanup); Section 8, exposure controls and personal protection (PPE); Section 13, disposal considerations.
- A spray bottle filled from a labeled jug and left out for others is a workplace container. It needs the product identifier plus words, pictures or symbols showing its hazards, not just initials and a date.
- Training is required when a worker is first assigned and again whenever a new chemical hazard enters the work area. It does not wait for an exposure or a request.
- To dispose of a chemical, check SDS Section 13 together with the facility's waste policy. Instrument and sterilizer manuals do not cover chemical waste.
Eyewash and chemical splashes
- OSHA 29 CFR 1910.151(c): where corrosive materials could reach the eyes or body, the employer must provide facilities for quick drenching or flushing inside the work area, ready for immediate emergency use.
- Somewhere else in the building does not meet the rule, and safety glasses or small saline drops do not replace flushing equipment.
- OSHA's Hospitals eTool for central supply says that if glutaraldehyde gets on the skin, use an eyewash fountain or emergency shower and rinse the skin with water for 15 minutes or longer.
- Do not stop when the stinging fades; that can happen before the chemical is gone.
Key terms
- Negative pressure
- A room held at lower air pressure than its neighbors, so air flows into it; used for decontamination.
- Positive pressure
- A room held at higher air pressure than its neighbors, so air flows out of it; used for sterile storage.
- Air changes per hour
- How many times the full volume of a room's air is replaced in one hour.
- Relative humidity
- The amount of moisture in the air, given as a percentage of the most the air could hold at that temperature.
- Smoke tube
- A device that releases a visible wisp at a doorway so staff can see which way air is moving.
- Flutter strip
- A light paper or plastic strip hung at a door gap that bends in the direction of airflow.
- Safety Data Sheet (SDS)
- A 16-section document from the maker of a chemical describing its hazards, safe handling, first aid, spill response and disposal.
- Hazard Communication Standard
- OSHA rule 29 CFR 1910.1200 requiring chemical labels, data sheets and worker training about chemical hazards.
- Workplace container
- A bottle or other vessel a worker fills from the original product for use on the job; it must be labeled.
- Product identifier
- The name or number on a chemical's label that links it to its matching data sheet.
- Eyewash station
- Plumbed or self-contained equipment that flushes the eyes with a steady stream of water after a chemical splash.
- Glutaraldehyde
- A high-level disinfecting chemical that can sting the eyes, inflame the skin and irritate the airways.
Common mistakes
- Mixing up the two pressures: decontamination is negative (air flows in), sterile storage is positive (air flows out). Positive pressure in decontamination would push dirty air toward clean spaces.
- Giving the wrong number for the source named: CDC's 2003 table lists 6 air changes per hour for the decontamination room (4 is clean workroom and sterile storage, 2 is clean linen storage, 15 is operating rooms); AAMI's 10 is a different source.
- Answering 30% or 50% for the sterile storage humidity ceiling in CDC 2008. The 30%-60% range is for work areas; sterile storage may go up to 70%.
- Fixing an airflow problem yourself by opening doors, moving soiled carts to the clean side or turning off ventilation. Report it, keep doors shut and let engineering correct it.
- Picking the wrong SDS section: first aid is Section 4, spill cleanup is Section 6, PPE is Section 8 and disposal is Section 13.
- Thinking a refilled spray bottle needs no label because the source jug is labeled, or that an eyewash anywhere in the building is enough.
Checked against: CDC, Guidelines for Environmental Infection Control in Health-Care Facilities (2003, updated 2019), PDF; CDC, Guideline for Disinfection and Sterilization in Healthcare Facilities (2008, updated), PDF; CDC, Disinfection and Sterilization Guideline: Sterilizing Practices; CDC, Best Practices for Environmental Cleaning in Healthcare Facilities in Resource-Limited Settings; OSHA, 29 CFR 1910.1200 Hazard Communication; OSHA, 29 CFR 1910.151 Medical services and first aid; OSHA Hospitals eTool, Central Supply: Hazardous Chemicals