This topic covers how supplies are stocked and sent to units (PAR levels, exchange carts, case carts, code carts), inventory models such as just-in-time and consignment, receiving checks, Unique Device Identifiers and how FDA recalls work. Expect some simple arithmetic and several "which system is this?" questions.
PAR levels and restocking math
- A PAR level is the set quantity of an item a location is supposed to hold.
- At each restock, count what is on hand and bring the stock back up to PAR.
- Amount to deliver = PAR level − quantity on hand. Do not add the two, and do not send a full PAR on top of what is there.
- A PAR level is a stocking quantity; it is not a shelf-life limit or a contract price.
Example
A unit's PAR for IV start kits is 20. The restock count finds 7 on the shelf. How many kits should be delivered?
Solution
20 − 7 = 13 kits. After delivery the shelf holds 7 + 13 = 20, which equals PAR. Sending 20 would leave 27, above PAR.
Cart systems
- **PAR level cart:** a mobile cart that is counted and topped back up to its PAR.
- **Exchange cart:** identical carts take turns. A full cart replaces the used one on the unit, and the used cart goes back to be counted and refilled.
- **Case cart:** holds the instruments and supplies for one specific surgical procedure and goes to the operating room; after the case it carries the used items back.
- Return used instruments in a closed case cart (walls and doors around the shelves) sent to decontamination, never through sterile storage. Closed carts can show biohazard labels on every side.
- Do not carry used trays back by hand or wrap them in used drapes with clean linen.
- **Code (crash) cart:** carries emergency drugs and equipment for life-threatening events. Contents and layout differ between hospitals, so restock it from your current facility's approved list, not from memory of another hospital or from recent requests.
Inventory models
- **Just-in-time (JIT):** goods arrive only as they are needed. Less stock on site means lower cost and less waste, but a delivery disruption can leave little or nothing to fall back on.
- JIT does not remove receiving checks and does not change how items are identified.
- **Consignment:** the supplier owns stock kept at the hospital, and the hospital pays only for items it uses. For example, a vendor may keep implants on site and bill only for those used.
- Consignment is about who owns the stock; JIT is about when stock arrives; PAR and exchange carts are about how hospital-owned stock is refilled.
- **Low turnover:** items that sit on the shelf a long time suggest overstocking and lead to obsolete or expired stock. The fix is lower stock levels for slow movers plus first-in, first-out rotation, not higher levels.
- Expired items are never moved to the front to be used first; they are not issued at all.
Receiving and unit of measure
- Sterile supplies often arrive in corrugated cartons. Unpack them in a separate area outside sterile storage, then shelve the items. Cartons are not taken into sterile storage or used where clean or sterile items are kept.
- Check each package, not just the packing slip or outer carton: it must be intact and in date. CDC says a sterile item should not be used once expired or if its package is wet, torn or punctured.
- Set damaged or expired items aside; they are not shelved or issued.
- Devices are packed in fixed quantities (each, box, case). A request for "2" of an item issued by the box of 50 could mean 2 catheters or 100, so every request must state its unit of measure.
- When a vendor loaner set with implants is sterilized in-house, CDC calls for a biological indicator in every load containing implants, with the implants quarantined until the result is negative whenever possible.
Unique Device Identifier (UDI)
- A UDI lets a device be identified from distribution through use. It has two parts.
- **Device identifier (DI):** the fixed, required part that names the labeler and the exact model or version.
- **Production identifier (PI):** the variable part, used when it applies: lot or batch number, serial number, expiration date and manufacturing date. Look here for lot and expiration.
- FDA's Global Unique Device Identification Database (GUDID) stores only the DI, not the PI.
- The label must show the UDI both as plain text people can read and in a machine-readable form (automatic identification and data capture, such as a barcode).
- Scanning UDIs at receiving and issue lets a facility find which recalled devices it holds, and where, much faster and more precisely.
Device recalls
- FDA uses "recall" for either a **correction** (fixing the problem where the device is used, such as checking, adjusting or repairing it) or a **removal** (taking it out of where it is used or sold).
- A recall does not always mean returning every unit or stopping use; it may mean checking, adjusting or fixing the device, so follow the recall notice.
- **Class I:** there is a reasonable chance the product could lead to serious health problems or death. The most serious class.
- **Class II:** the product may lead to a temporary or reversible health problem, or carries a slight chance of serious harm.
- **Class III:** unlikely to cause any injury or health problem.
- FDA sets the class. A facility's tracking helps it respond but cannot change the class or keep recalled items in use until they expire.
Key terms
- PAR level
- The set quantity of an item a location should hold; restocking brings it back to that number.
- Exchange cart
- One of a set of identical stocked carts; a full one is swapped in while the used one is refilled.
- Case cart
- A cart holding the instruments and supplies for one surgical procedure, which then returns the used items.
- Code cart
- A crash cart of emergency drugs and equipment, stocked to the facility's approved contents list.
- Just-in-time inventory
- Receiving supplies only as they are needed, which lowers stock on hand but leaves little backup.
- Consignment inventory
- Supplier-owned stock kept at the facility, paid for only when an item is used.
- Inventory turnover
- How quickly stock is used and replaced; slow movement points to overstock and expiring items.
- Unit of measure
- The packaging quantity an item is counted and issued in, such as each, box or case.
- Unique Device Identifier (UDI)
- An FDA-required code on device labels that lets a device be identified from distribution through use.
- Device identifier (DI)
- The fixed part of a device's label code naming the labeler and the model or version.
- Production identifier (PI)
- The variable part of a device's label code: lot, serial number, expiration and manufacture dates.
- GUDID
- FDA's Global Unique Device Identification Database, which stores the device-identifier portion of each UDI.
- AIDC
- Automatic identification and data capture: machine-readable formats such as barcodes.
- Class I recall
- FDA's most serious recall category: a reasonable chance of serious health problems or death.
- Correction
- A recall action that fixes a device problem where the device is used, without removing it.
- Quarantine
- Holding processed items back from use until test results, such as a biological indicator, come back negative.
Common mistakes
- Getting PAR math backward: deliver PAR minus on-hand (20 − 7 = 13), not the on-hand count, not a full PAR, and not the sum.
- Mixing up cart systems: an exchange cart swaps a whole stocked cart, a case cart serves one surgery, a code cart holds emergency items, and on-demand or vendor-direct delivery is neither.
- Calling vendor-owned, pay-when-used stock just-in-time, or thinking JIT increases on-site stock. JIT lowers stock; consignment is about ownership.
- Looking for lot and expiration in the DI or in GUDID. They are in the production identifier, and GUDID holds only the DI.
- Believing every recall means shipping all units back. A recall can be a correction made in place; follow the recall notice.
- Taking shipping cartons into sterile storage or to the unit, or checking only the packing slip. Unpack outside sterile storage and check each package for damage and date.
Checked against: Infor CloudSuite Healthcare documentation, Par location; CADTH Rapid Review RC1512, Case Carts in Operating Rooms (Canadian Journal of Health Technologies, 2023); Wikipedia, Crash cart; Wikipedia, Just-in-time manufacturing; Wikipedia, Consignment stock; Wikipedia, Inventory turnover; Wikipedia, Stock rotation; Winnipeg Regional Health Authority, Transportation, Distribution, and Storage of Contaminated, Clean and Sterile Medical Devices (operational directive, 2023); CDC, Disinfection and Sterilization Guideline: Sterilizing Practices; CDC, Guideline for Disinfection and Sterilization in Healthcare Facilities (2008, updated), PDF; 21 CFR 801.3, Definitions (Cornell LII); FDA, UDI Basics; FDA, Benefits of a UDI System; FDA, What is a Medical Device Recall?