Study these as flashcardsSterilization parameters

Work Environment, Air and Chemical Safety

Negative pressure:
A room held at lower air pressure than its neighbors, so air flows into it; used for decontamination.
Positive pressure:
A room held at higher air pressure than its neighbors, so air flows out of it; used for sterile storage.
Air changes per hour:
How many times the full volume of a room's air is replaced in one hour.
Relative humidity:
The amount of moisture in the air, given as a percentage of the most the air could hold at that temperature.
Smoke tube:
A device that releases a visible wisp at a doorway so staff can see which way air is moving.
Flutter strip:
A light paper or plastic strip hung at a door gap that bends in the direction of airflow.
Safety Data Sheet (SDS):
A 16-section document from the maker of a chemical describing its hazards, safe handling, first aid, spill response and disposal.
Hazard Communication Standard:
OSHA rule 29 CFR 1910.1200 requiring chemical labels, data sheets and worker training about chemical hazards.
Workplace container:
A bottle or other vessel a worker fills from the original product for use on the job; it must be labeled.
Product identifier:
The name or number on a chemical's label that links it to its matching data sheet.
Eyewash station:
Plumbed or self-contained equipment that flushes the eyes with a steady stream of water after a chemical splash.
Glutaraldehyde:
A high-level disinfecting chemical that can sting the eyes, inflame the skin and irritate the airways.

Attire, Traffic Control and Ergonomics

Hand hygiene:
Cleaning the hands by washing with soap and water or rubbing in an alcohol-based product.
Alcohol-based hand sanitizer:
A rub-in hand product preferred by CDC when hands are not visibly soiled; rub until dry, about 20 seconds.
Visibly soiled hands:
Hands with dirt, blood or other matter you can see; they must be washed with soap and water.
Gram-negative bacteria:
A large group of bacteria, including Pseudomonas and Klebsiella, found more often on the fingertips of workers wearing artificial nails.
Bloodborne Pathogens standard:
OSHA rule 29 CFR 1910.1030 that protects workers exposed to blood and other potentially infectious materials.
Traffic control:
Limiting who enters each area and how people and items move, so contamination does not travel from dirty to clean.
One-way workflow:
Moving items only from decontamination to packaging to sterilization to storage, never back toward dirty areas.
Limited-access area:
A space, such as sterile storage, entered only by staff who need to work there.
Ergonomics:
Fitting a job to a person to reduce fatigue and work-related muscle, nerve and tendon injuries.
Musculoskeletal disorder (MSD):
An injury or illness of the muscles, nerves, tendons, ligaments or blood vessels, often from repeated strain.
Engineering control:
A physical change to the workplace, such as an adjustable table, that removes or reduces a hazard; OSHA's top choice.
Administrative control:
A rule or procedure, such as job rotation or scheduled breaks, used when physical changes are not enough.
Power zone:
The safest lifting area: between knee and shoulder height, with the load held near the body.

Regulations, Standards, Records and Quality

FDA:
Federal agency that regulates medical device makers and clears sterilants and high-level disinfectants for devices.
EPA:
Federal agency that registers disinfectants for environmental surfaces such as floors and countertops.
OSHA:
Federal agency that sets and enforces rules to keep workers safe and healthy on the job.
Conditions of Participation:
CMS health and safety requirements an organization must meet to take part in Medicare and Medicaid.
Deemed status:
Recognition that a facility accredited by a CMS-approved organization meets Medicare requirements.
Consensus standard:
A voluntary practice document written by a standards development organization such as AAMI.
Instructions for use (IFU):
The manufacturer's validated written directions for using, cleaning and processing a specific device.
FIFRA:
The federal pesticide law under which EPA registers surface disinfectants and makes their labels legally binding.
Load number:
A code on each package linking it to the sterilizer cycle that processed it, for tracing and recalls.
MedWatch:
FDA's program for safety information and adverse event reports; voluntary reports use Form FDA 3500.
User facility reporting:
FDA rule requiring hospitals to report device-related deaths and serious injuries within 10 work days.
Competency testing:
Documented checks that a worker can do each task correctly, done at hire and regularly after.
PDSA:
Plan-Do-Study-Act: an improvement cycle built on small tests of change before wider adoption.
Lean:
An improvement method that raises efficiency by removing steps that add no value.
Six Sigma:
A data-driven improvement method that reduces variation and defects using Define-Measure-Analyze-Improve-Control.
Root cause analysis (RCA):
A structured review of a serious event to find underlying system problems instead of individual blame.

Decontamination Safety, PPE and Microbiology

Chain of infection:
Five linked steps (reservoir, exit, transmission, entry, host) that an infection needs; breaking one stops it.
Fomite:
Inanimate object, such as a used instrument, that carries organisms from one person to another.
Indirect transmission:
Spread of an infectious agent through a go-between such as an object, air particle or insect.
Biofilm:
Community of microbes tightly attached to a surface, far more resistant to germicides than free-floating cells.
Bacterial spore:
Dormant bacterial form protected by a coat and cortex; the most chemical-resistant organism after prions.
Mycobacteria:
Bacteria such as M. tuberculosis whose waxy cell wall makes them resist many disinfectants.
Exposure incident:
Blood or infectious material reaching eye, mouth, mucous membrane, broken skin or a puncture during work.
Engineering control:
Device that isolates or removes a hazard, such as a sharps container.
Work practice control:
Change in how a task is done to cut exposure, such as no eating in the work area.
Hepatitis B declination:
Signed form refusing the HBV vaccine; the worker may still accept the shots later, free.
Post-exposure evaluation:
Confidential, free medical assessment and follow-up the employer provides after an exposure incident.
Biohazard label:
Fluorescent orange or orange-red warning tag with the symbol; red bags or containers may substitute.
Donning:
Putting on protective gear in order: gown, mask, eye protection, then gloves over the cuffs.
Doffing:
Removing protective gear; in CDC's first example gloves come off first and the mask last.
Prion:
Infectious protein that causes CJD and is not reliably inactivated by routine reprocessing.
High-infectivity tissue:
For CJD: brain, spinal cord and eye, which call for special instrument reprocessing.

Manual and Mechanical Cleaning

Point-of-use treatment:
Keeping used instruments open and moist right after the procedure; it starts but never replaces cleaning.
Friction:
Rubbing or scrubbing soil off with a brush or cloth; one of two essentials of manual cleaning.
Fluidics:
Fluid forced under pressure through channels to flush out soil, especially where a brush cannot pass.
Enzymatic cleaner:
Detergent with proteases (and sometimes lipases or amylases) that digests soil but kills no microbes.
Neutral pH detergent:
Cleaning solution that is neither acidic nor alkaline; with enzymes it is CDC's preferred choice for delicate instruments and flexible endoscopes.
Alkaline cleaner:
High-pH detergent that dissolves protein and fat efficiently but can corrode devices.
Cavitation:
Formation and implosion of tiny bubbles from sound waves, which pulls debris off instruments in an ultrasonic unit.
Degassing:
Running a freshly filled ultrasonic unit with the lid closed for 5 to 10 minutes to remove dissolved gas.
Impingement:
Pressurized water spray that physically knocks soil off; the main cleaning action of a washer-disinfector.
Thermal rinse:
Final hot-water step of a washer-disinfector cycle that disinfects by heat.
Test soil:
Commercial product mimicking dried blood, used to check that a washer-disinfector is cleaning properly.
Cart washer:
Machine for carts, rigid containers and basins; lacks enzymatic wash and lubrication steps.
Pyrogen-free water:
Water free of fever-causing substances such as endotoxin; required for final rinsing of intravascular device lumens.
TASS:
Toxic anterior segment syndrome: acute, noninfectious eye inflammation after anterior segment surgery, often from instrument residue.
Single-use device:
Item intended for one use or one patient in one procedure, then discarded.
Instructions for use (IFU):
Manufacturer's written directions for reprocessing a device or using a chemical; they set disassembly, dilution, temperature and method.

Spaulding Classification and Disinfection

Critical item:
Device entering sterile tissue or the vascular system, such as a surgical instrument; must be sterile.
Semicritical item:
Device touching mucous membranes or nonintact skin, such as a laryngoscope blade; needs at least high-level disinfection.
Noncritical item:
Device touching only intact skin, such as a blood pressure cuff; needs low-level disinfection.
High-level disinfection:
Process killing all microorganisms except small numbers of bacterial spores.
Intermediate-level disinfectant:
Chemical that kills vegetative bacteria including tubercle bacilli, fungi, lipid and some nonlipid viruses, but not spores.
Low-level disinfectant:
Chemical that kills most vegetative bacteria, lipid viruses and some fungi, but not tubercle bacilli or spores.
Chemical sterilant:
Germicide that kills spores when given long contact, often 3 to 12 hours.
Minimum effective concentration (MEC):
Lowest strength at which a reusable disinfectant still meets its label claim; checked with test strips.
Reuse life:
Maximum number of days a reusable solution may be used, set by its manufacturer, regardless of strip results.
Glutaraldehyde:
Metal-safe high-level disinfectant whose vapor irritates airways and skin; needs ventilation and nitrile or butyl gloves.
Ortho-phthalaldehyde (OPA):
High-level disinfectant that stains proteins, including unprotected skin, gray.
Peracetic acid:
Sporicidal chemical leaving no residue that can corrode copper, brass, bronze and plain steel.
Sodium hypochlorite:
Bleach; fast and cheap but corrosive at high strength and releases chlorine gas with ammonia or acid.
Quaternary ammonium compound:
Low-level surface disinfectant for noncritical items; not sporicidal and generally not tuberculocidal.
FIFRA:
Federal law under which EPA registers disinfectants; using a product against its label is a violation.
Phenolic:
EPA-registered surface disinfectant, not cleared for high-level use, kept off occupied infant bassinets.

Instrument Inspection, Testing and Care

Box lock:
The hinged joint where the two halves of a clamp or hemostat cross; a common place for hidden soil and cracks.
Serrations:
Grooves or ridges cut into instrument jaws to improve grip; they trap debris and need close inspection.
Ratchet:
Interlocking teeth near the finger rings that hold an instrument's jaws closed at set positions.
Function check:
Testing that an instrument works as intended, such as jaw alignment, ratchet hold, smooth hinges and sharp edges.
Retained soil:
Blood, tissue or other debris left on a device after cleaning, which can shield microbes from sterilization.
Insulation tester:
A device that detects breaks in the coating of electrosurgical instruments that could let current escape.
Cannulated device:
An instrument with a hollow channel, such as a suction tip, checked to confirm the channel is open.
Passive layer:
The thin chromium and iron oxide film on stainless steel that protects it from rust.
Pitting:
Small dark holes where metal has been lost to corrosion, often from blood, chlorides or harsh solutions.
Spotting:
Loose deposits sitting on an instrument's surface, often minerals from hard water, that can be wiped away.
Galvanic corrosion:
Metal transferring from one metal to another when dissimilar metals share a solution, leaving rainbow, gold or rusty tints.
Water-soluble lubricant:
An instrument lubricant that dissolves in water, so it does not block sterilant from reaching the metal.
Instructions for use (IFU):
The manufacturer's written directions for cleaning, testing, lubricating and sterilizing a specific device.
Deionized water:
Water with dissolved minerals removed, used for final rinsing to prevent spots and deposits.

Set Assembly and Chemical Indicators

Tray list:
The count sheet naming every device a set should contain, used to check completeness during assembly.
Stringer:
A pin or rack that holds ringed instruments together, open, inside a tray.
First ratchet:
The lightest locked position on a ratcheted instrument, the only closed position allowed in a set.
Tip protector:
A cover over a sharp end, validated for steam penetration and fitted loosely enough for sterilant to reach.
Wet pack:
A package with moisture inside the case or tray after the cycle ends; its contents are considered contaminated.
External chemical indicator:
A marker on the outside of a package showing it went through a cycle, not that it is sterile.
Internal chemical indicator:
A marker placed inside a package to show the sterilant reached the contents.
Process indicator:
ISO 11140 Type 1; shows a pack was exposed to the process, separating processed from unprocessed units.
Integrating indicator:
ISO 11140 Type 5; reacts to all critical variables and is meant to equal or exceed biological indicator performance requirements.
Emulating indicator:
ISO 11140 Type 6; reacts to all critical variables and matches those of a specified cycle.
Bowie-Dick test:
A daily empty-chamber check of air removal and air leaks in a prevacuum steam sterilizer.
Biological indicator:
A test containing resistant spores; the only monitor that measures whether a cycle killed microbes.
Quarantine:
Holding processed items back from use until a pending test result, such as a spore test, comes back.
Loaner set:
Instruments borrowed from a vendor or another facility for a procedure, processed here per the maker's instructions before use.
Immediate-use steam sterilization:
A shortened steam cycle for items needed at once; the WHO manual says never to use it for implants.

Packaging Methods and Labeling

Sterile barrier:
Packaging that lets sterilant in, then blocks microbes so contents stay sterile until opened.
Sequential wrapping:
Two sheets wrapped one after the other, creating a package within a package.
Simultaneous wrapping:
Two sheets laid together and folded as one, giving two layers with a single wrapping step.
Envelope fold:
A wrapping method with the set placed diagonally, slightly off center, and the corners folded over it.
Square fold:
A wrapping method, also called parcel fold, with the set centered and parallel to the wrap's long edge.
Tenting:
Loose wrap standing away from the contents, leaving air pockets that can compromise the barrier.
Peel pouch:
A heat-sealed paper-plastic or synthetic package for a single, lightweight device.
Heat sealer:
A machine that closes pouches with heat and pressure; tested daily and calibrated at least yearly.
Rigid container:
A reusable metal or polymer box with filtered vents, used mainly for large steam-sterilized sets.
Tyvek:
A synthetic polyolefin material with low chemical absorption, suitable for hydrogen peroxide plasma packaging.
Load number:
Label code identifying the sterilizer, the cycle or load, the date and any expiration date.
Event-related shelf life:
Treating an item as sterile until damage, moisture, a broken seal or other event compromises it.
Batch control label:
A peel-off label recording lot details, placed in the patient's record to allow tracing and recall.
Indicator tape:
Adhesive tape that closes wrapped packs and carries a process indicator that changes color in a cycle.

Steam and High-Temperature Sterilization

Gravity displacement:
Air removal in which incoming steam, lighter than air, pushes air down and out through a drain near the bottom.
Dynamic air removal:
Active air removal before exposure, either by vacuum pulses (prevacuum) or by steam flushes and pressure pulses.
Prevacuum sterilizer:
Steam unit that uses a vacuum pump or ejector to pull air out of the chamber and load before exposure.
Steam-flush pressure-pulse:
Air-removal method using repeated steam flushes and pulses above atmospheric pressure, so leaks cannot draw air in.
Conditioning:
First cycle phase, when air is removed and the load is heated.
Exposure time:
Period the load is held at the set sterilizing temperature.
Jacket:
Steam-filled space around the chamber that preheats it and helps dry the load.
Door gasket:
Seal between the door and chamber that keeps steam and pressure inside.
Thermostatic trap:
Drain-line device that lets condensate leave the chamber, helping loads dry.
Drain strainer:
Screen over the chamber drain that catches lint and debris; clean it daily.
Dryness fraction:
Share of steam that is vapor rather than liquid water; at least 97% is the goal.
Wet pack:
Package with dampness, droplets or puddles on or inside it after the cycle; treated as contaminated.
Immediate-use steam sterilization:
Unwrapped steam processing of an item needed right away; also called flash; no storage afterward.
Porous item:
Item that can trap air or liquid, such as fabric, rubber, plastic or a device with a lumen.

Low-Temperature Sterilization

Ethylene oxide (EtO):
Flammable, carcinogenic sterilant gas used for heat- and moisture-sensitive devices; requires aeration afterward.
Aeration:
Holding items after an EtO cycle, in an aerator or room, until the gas they absorbed has left them.
Preconditioning:
First EtO cycle stage, when the load is brought to set conditions and humidified before gas enters.
Permissible exposure limit (PEL):
OSHA's maximum allowed worker exposure; for EtO, 1 ppm averaged over 8 hours.
Excursion limit:
OSHA's short-term EtO cap: 5 ppm averaged over 15 minutes.
Action level:
EtO exposure of 0.5 ppm over 8 hours; reaching it 30 or more days a year requires medical surveillance.
Time-weighted average (TWA):
A worker's average airborne chemical concentration across a set sampling period, such as an 8-hour shift.
Hydrogen peroxide gas plasma:
Low-temperature vacuum process using peroxide vapor and plasma; leaves water and oxygen, so no aeration.
Cellulose:
Plant-based material such as paper or cotton linen; absorbs hydrogen peroxide, so it cannot go in peroxide sterilizers.
Polyolefin pouch:
Synthetic (Tyvek-type) peel pouch acceptable for hydrogen peroxide sterilization.
Peracetic acid system:
Automated liquid immersion sterilizer for immersible heat-sensitive instruments; items must be used immediately.
Channel connector:
Fitting that links an endoscope's lumens to the processor so liquid sterilant flows through them.
Ozone sterilizer:
Low-temperature unit that generates its oxidizing gas from oxygen, water and electricity, then converts it back with a catalyst.
Dry heat:
Hot-air sterilization, e.g. 170°C for 60 minutes, for powders, oils and petroleum products.

Sterilizer Testing, Load Release and Recalls

Physical monitor:
Printout, graph or display showing a cycle's time, temperature and pressure; also called mechanical monitoring.
External chemical indicator:
Indicator on a package's outside showing only that it was exposed to a sterilization process.
Internal chemical indicator:
Indicator placed inside a package to show sterilant reached the contents.
Process indicator:
ISO Type 1 marker, such as tape, separating processed from unprocessed packages.
Integrating indicator:
ISO Type 5 device reacting to all critical variables, designed to perform at or beyond BI requirements.
Emulating indicator:
ISO Type 6 device reacting to all critical variables, matched to the specific cycle on its label.
Bowie-Dick test:
Daily empty-chamber air-removal check for prevacuum steam sterilizers, run before the first load.
Leak test:
Vacuum check of whether a prevacuum chamber is airtight, run on the sterilizer maker's schedule.
Biological indicator (BI):
Carrier of resistant spores that shows whether a cycle actually killed organisms.
Geobacillus stearothermophilus:
Spore-former used to monitor steam (and per CDC peroxide plasma and peracetic acid); incubated at 55-60°C.
Bacillus atrophaeus:
Spore-former used to monitor EtO and dry heat; incubated at 35-37°C.
Control BI:
Unprocessed indicator from the same lot, incubated to prove the spores could grow.
Process challenge device (PCD):
Test pack or tray that challenges the cycle and holds a BI, integrating indicator or enzyme-only indicator.
Quarantine:
Holding processed items, such as implants, until monitoring results allow release.
Recall:
Retrieving items from suspect loads so they can be reprocessed and patient exposure assessed.
Load label:
Package marking naming the sterilizer, cycle or load number, date and any expiration, enabling tracing.

Sterile Storage, Shelf Life and Transport

Sterile storage:
A limited-access area with controlled temperature and humidity where processed packs are kept until issue.
Event-related shelf life:
The practice of treating a pack as sterile until damage, wetting or another event compromises it.
Time-related shelf life:
The practice of labeling packs with an expiration date and reprocessing them once that date passes.
Package integrity:
The condition of a wrap, pouch or container being whole, dry and sealed, with no tears or punctures.
Impervious packaging:
Material, such as heat-sealed plastic, that does not let moisture or microbes pass through.
Stock rotation:
Placing newer items behind older ones so the oldest are used first; also called first in, first out.
First in, first out (FIFO):
Using the oldest stock of an item before newer deliveries of the same item.
Open shelving:
Uncovered racks for supplies; allowed by CDC, though closed or covered cabinets are ideal.
Sprinkler clearance:
The 18-inch space CDC calls for between stored items and a ceiling fire sprinkler head.
Corrugated cardboard:
Ridged material used for shipping boxes; such boxes are never taken into sterile storage areas.
Closed cart:
A transport cart with walls, doors or a cover that protects its load while outside the department.
Reprocessing:
Repeating cleaning, inspection, packaging and sterilization so an item can be used safely again.

Inventory, Supply Chain and Distribution

PAR level:
The set quantity of an item a location should hold; restocking brings it back to that number.
Exchange cart:
One of a set of identical stocked carts; a full one is swapped in while the used one is refilled.
Case cart:
A cart holding the instruments and supplies for one surgical procedure, which then returns the used items.
Code cart:
A crash cart of emergency drugs and equipment, stocked to the facility's approved contents list.
Just-in-time inventory:
Receiving supplies only as they are needed, which lowers stock on hand but leaves little backup.
Consignment inventory:
Supplier-owned stock kept at the facility, paid for only when an item is used.
Inventory turnover:
How quickly stock is used and replaced; slow movement points to overstock and expiring items.
Unit of measure:
The packaging quantity an item is counted and issued in, such as each, box or case.
Unique Device Identifier (UDI):
An FDA-required code on device labels that lets a device be identified from distribution through use.
Device identifier (DI):
The fixed part of a device's label code naming the labeler and the model or version.
Production identifier (PI):
The variable part of a device's label code: lot, serial number, expiration and manufacture dates.
GUDID:
FDA's Global Unique Device Identification Database, which stores the device-identifier portion of each UDI.
AIDC:
Automatic identification and data capture: machine-readable formats such as barcodes.
Class I recall:
FDA's most serious recall category: a reasonable chance of serious health problems or death.
Correction:
A recall action that fixes a device problem where the device is used, without removing it.
Quarantine:
Holding processed items back from use until test results, such as a biological indicator, come back negative.

Patient Care Equipment

Noncritical item:
Equipment that touches only intact skin or no patient at all; needs cleaning plus low-level disinfection.
Spaulding classification:
A system sorting devices as critical, semicritical or noncritical by infection risk, which sets the processing level.
Low-level disinfection:
Killing most vegetative bacteria and some fungi and viruses; the level CDC recommends for noncritical items.
Contact time:
How long a disinfectant must stay wet on a surface to work, as stated on its label.
EPA-registered disinfectant:
A surface germicide whose label claims and directions are approved by the Environmental Protection Agency and legally binding.
Cross-contamination:
Spread of microbes from soiled items or surfaces to clean ones.
Single-patient-use item:
A part, such as a compression sleeve, meant for one patient and discarded rather than reprocessed.
Biomedical (Clinical) Engineering:
The hospital department that inspects, maintains and repairs medical equipment.
Preventive maintenance (PM):
Scheduled inspection, testing and servicing of equipment by qualified staff, documented on a label or record.
Grounding prong:
The third plug pin that keeps equipment connected to ground; altering it or bypassing it with an adapter is prohibited.
Function check:
A test before issue that equipment powers on and works as its manufacturer's instructions describe.
Equipment inventory:
A list of all hospital equipment, owned or leased, with each item's maintenance record.

Communication, Teamwork and Professional Growth

Protected health information (PHI):
Identifiable information about a person's health, care or payment for care, in any form: paper, electronic or spoken.
HIPAA:
The federal law whose Privacy Rule sets how health care organizations must protect identifiable patient information.
Minimum necessary:
The rule that uses and disclosures of patient information are limited to what the task actually requires.
Workforce:
Employees, volunteers, trainees and others under a facility's direct control, whether paid or not.
Business associate:
An outside person or company that handles patient information on a covered entity's behalf.
Hostile work environment:
A workplace made offensive by harassment that is severe or frequent, based on a protected trait.
Mutual support:
Team members checking each other's work and offering help when a teammate is overloaded.
SBAR:
A four-part reporting script: Situation, Background, Assessment, Recommendation.
Handoff:
Passing responsibility for work, and the information about it, from one person or shift to the next.
Near miss:
An event that did not injure a patient only because of luck or a timely catch.
Culture of safety:
A workplace where staff report errors without fear of blame so system causes can be fixed.
Just culture:
An approach that fixes system problems while still holding people accountable for risky or reckless choices.
Continuing education (CE):
Ongoing learning credits; CRCST renewal needs 12 technical, sterile processing credits each year.
Suspension:
The status after a missed renewal: not considered certified and not allowed to use the title.
Grace period:
The six weeks after a missed renewal date when late CE and fees can still be submitted.

Medical Terminology and Instruments

-ectomy:
Suffix meaning to cut out or surgically remove.
-otomy:
Suffix meaning a surgical incision or cutting into, without necessarily removing anything.
-ostomy:
Suffix meaning a surgically created opening from inside the body to the outside.
-plasty:
Suffix meaning surgical repair or reconstruction.
-scopy:
Suffix meaning examination of the inside of the body with a viewing instrument.
Stoma:
The opening on the skin created by an ostomy procedure.
Supine:
Lying flat on the back, face up.
Prone:
Lying flat on the front, face down.
Proximal:
Closer to the point where a limb attaches to the trunk.
Distal:
Farther from the point where a limb attaches to the trunk.
Sagittal plane:
A vertical plane that divides the body into right and left parts.
Frontal (coronal) plane:
A vertical plane that divides the body into front and back parts.
Transverse plane:
A horizontal plane that divides the body into upper and lower parts.
Hemostat:
A locking clamp with serrated jaws used to close off blood vessels and control bleeding.
Box lock:
The pinned hinge of a ringed instrument that keeps the jaw tips aligned.
Ratchet:
Interlocking teeth near the finger rings that hold an instrument's jaws closed.
Serrations:
Grooves cut across an instrument's jaws to help them grip tissue.
Tungsten carbide insert:
A very hard, wear-resistant jaw or blade piece, usually marked by gold handles.
Self-retaining retractor:
A tissue-spreading instrument that holds itself open with a ratchet or similar mechanism, needing no assistant.
Rongeur:
A sturdy bone-cutting instrument whose sharp, scoop-shaped tip bites off pieces of bone.

Know the terms? Test them: free CRCST practice test · study guide.